Sensors
pH
Many differing configurations are available to suit both clean water and waste water applications.Waste water applications can be challenging to measure, however our range of large reference electrodes and refillable probes are well suited to these applications.
Built-in temperature compensation is available, simplifying the installation.
Transducers are available for applications where the sensor is some distance for the analyser / controller.
Chlorine
These sensors are of the amperometric design and as such do not require the dosing of buffers or reagents. The sample water is therefore able to be reused within the process. These units are widely used within the water authorities throughout Australia.The package of controller / analyser, probe and probe holder is very compact and user friendly. Calibrations are a simple process, requiring only span adjustment.
Due to the high stability of these units, maintenance is reduced to periodic calibration only.
ORP (Redox)
Many differing configurations are available to suit both clean water and waste water applications.Waste water applications can be challenging to measure, however our range of large reference electrodes are well suited to these applications.
Transducers are available for applications where the sensor is some distance for the analyser / controller.
Conductivity
Two electrode measuring cells and inductive sensors are offered for a variety of process applications. Temperature compensation can be offered integral to the sensor, thereby simplifying the application.Temperature
These sensors can be offered in glass or stainless steel.Peracetic Acid
These sensors are of the amperometric design and as such do not require the dosing of buffers or reagents. The sample water is therefore able to be reused within the process. These units are used within the food and beverage, cosmetic, pharmaceutical and medical industries.The package of controller / analyser, probe and probe holder is very compact and user friendly. Calibrations are a simple process, requiring only span adjustment.
Due to the high stability of these units, maintenance is reduced to periodic calibration only.
Chlorine Dioxide
These sensors are of the amperometric design and as such do not require the dosing of buffers or reagents. The sample water is therefore able to be reused within the process. The package of controller / analyser, probe and probe holder is very compact and user friendly. Calibrations are a simple process, requiring only span adjustment.Due to the high stability of these units, maintenance is reduced to periodic calibration only.
Ozone
These sensors are of the amperometric design and as such do not require the dosing of buffers or reagents. The sample water is therefore able to be reused within the process. The package of controller / analyser, probe and probe holder is very compact and user friendly. Calibrations are a simple process, requiring only span adjustment.Due to the high stability of these units, maintenance is reduced to periodic calibration only.
Dissolved Oxygen
Sensors can be supplied separately or as part of a stand-alone system. If supplied separately, the sensors can be used as a transmitter (4-20mA) to the clients central controller. As a stand-alone system the sensor can be supplied with an analyser / controller which displays dissolved oxygen in PPM.Sensors can be immersed or fitted on-line.
Fluoride
This sensor is supplied as part of a fully packaged system. The system utilises an ion selective electrode and a reference electrode. No special conditioning chemicals are required. Photometric measurement based calibration, is necessary only when commissioning and occasional intervals.Hydrogen Peroxide
These sensors are of the amperometric design and as such do not require the dosing of buffers or reagents. The sample water is therefore able to be reused within the process. These units are used within the food and beverage, cosmetic, pharmaceutical and medical industries. The package of controller / analyser, probe and probe holder is very compact and user friendly. Calibrations are a simple process, requiring only span adjustment.Due to the high stability of these units, maintenance is reduced to periodic calibration only.
Bromine
These sensors are of the amperometric design and as such do not require the dosing of buffers or reagents. The sample water is therefore able to be reused within the process.The package of controller / analyser, probe and probe holder is very compact and user friendly. Calibrations are a simple process, requiring only span adjustment.
Due to the high stability of these units, maintenance is reduced to periodic calibration only.
Accessories
Submersible Probe Holder
Flexible - Provides protection for probe from mechanical damage and ingress of liquids when submersed in pit or tank application. The flexible assembly allows for easy removal in restricted space or long insertion lengths into tanks and pits.Rigid - Provides protection for probe from mechanical damage and ingress of liquids when submersed in pit or tank application.
In-line Probe Holder
Provides mechanical protection and features a water sample valve. A sample water flow switch can be easily integrated into the assembly, as can a flow restriction valve.An in-line filter is available where suspended solids may affect the integrity of the system.